Home › Codes › SPN 3226 › FMI 20
SPN 3226 FMI 20
Aftertreatment 1 Outlet NOx — Data drifted high.
The value has slowly crept higher than expected over time.
What the SPN covers: NOx sensor reading in the exhaust after the SCR catalyst (tailpipe NOx). More on SPN 3226.
What FMI 20 usually points to: Sensor aging, contamination, or an offset problem. More on FMI 20.
Severity
MEDIUM — fix soon
A bad outlet sensor often triggers SCR efficiency faults and derates.
Likely causes
- Failed NOx sensor
- Real high NOx from poor DEF dosing
- Exhaust leak
- Sensor wiring or module fault
Checks & fixes (easiest first)
- Check DEF quality and dosing
- Check for exhaust leaks
- Check sensor wiring and power
- Run the OEM SCR performance test
FAQ
What does SPN 3226 FMI 20 mean?
Aftertreatment 1 Outlet NOx — data drifted high. The value has slowly crept higher than expected over time.
Is SPN 3226 FMI 20 serious?
A bad outlet sensor often triggers SCR efficiency faults and derates.
What should I check first for SPN 3226 FMI 20?
Check DEF quality and dosing; Check for exhaust leaks; Check sensor wiring and power.