Home › Codes › SPN 3226 › FMI 4
SPN 3226 FMI 4
Aftertreatment 1 Outlet NOx — Voltage below normal or shorted low.
The sensor circuit voltage is lower than it should ever be, usually near zero.
What the SPN covers: NOx sensor reading in the exhaust after the SCR catalyst (tailpipe NOx). More on SPN 3226.
What FMI 4 usually points to: Signal wire shorted to ground, a lost 5 V reference, or an open signal wire on a pulled-down circuit. More on FMI 4.
Severity
MEDIUM — fix soon
A bad outlet sensor often triggers SCR efficiency faults and derates.
Likely causes
- Wiring or connector fault in this circuit (most common for electrical FMIs)
- Failed NOx sensor
- Real high NOx from poor DEF dosing
- Exhaust leak
- Sensor wiring or module fault
Checks & fixes (easiest first)
- Inspect the connector and harness for this circuit: corrosion, water, chafing, backed-out pins
- Check the reference voltage, ground and signal at the component per OEM pin-out
- Check DEF quality and dosing
- Check for exhaust leaks
- Check sensor wiring and power
- Run the OEM SCR performance test
FAQ
What does SPN 3226 FMI 4 mean?
Aftertreatment 1 Outlet NOx — voltage below normal or shorted low. The sensor circuit voltage is lower than it should ever be, usually near zero.
Is SPN 3226 FMI 4 serious?
A bad outlet sensor often triggers SCR efficiency faults and derates.
What should I check first for SPN 3226 FMI 4?
Inspect the connector and harness for this circuit: corrosion, water, chafing, backed-out pins; Check the reference voltage, ground and signal at the component per OEM pin-out; Check DEF quality and dosing.